ABSTRACT:
Now days “save electricity and save high grade energy” are major concerns for societal needs. Various cooling methods are used to save energy as well as environment. To achieve comfort environment many techniques are used. The use of geothermal energy is one of the attractive ways to make environment healthy for mankind and to reduce the demand of electricity, which is increasing day by day. The Earth Air Heat Exchanger system is a better passive technology to the use of geothermal energy. In this research paper efforts are made to analyse the accomplishment of low cost cooling system of outdoor air for hot-dry climate. The effect of velocity, length and drop in temperature of air is studied at inlet and outlet of the pipe. The results of velocity variation reveal that for length of pipe 15 m and 1.5 m depth at velocities 4.8 m/s, 3.4 m/s and 2.5 m/s, the temperature drop is 4.2 °C, 7.5 °C and 9.2 °C respectively. The effect of variation in length of pipe has been studied and as per the measurements the temperature drops of 9.2 °C, 10.6 °C and 11.9 °C corresponding to length of 15 m, 30 m and 45 m for air velocity of 2.5 m/s and depth of 1.5 m. The maximum average temperature fall corresponding to 45 m length, at 1.5 m depth and at 2.5 m/s velocity is 8.6 °C. The results show that maximum temperature drop available at low velocities because air gets larger time to get heat transfer in the underground pipe in soil.


Cite this article:
Baljit Singh, A. K. Asati, Rakesh Kumar. Effect of parameters on Earth Air Heat Exchanger in Hot- dry climate. Research J. Engineering and Tech. 2018;9(1): 59-66 doi: 10.5958/2321-581X.2018.00009.0

Cite(Electronic):
Baljit Singh, A. K. Asati, Rakesh Kumar. Effect of parameters on Earth Air Heat Exchanger in Hot- dry climate. Research J. Engineering and Tech. 2018;9(1): 59-66 doi: 10.5958/2321-581X.2018.00009.0   Available on: https://ijersonline.org/AbstractView.aspx?PID=2018-9-1-9


Recomonded Articles:

Author(s): Piyush M. Kale, S. T. Bagde

DOI:         Access: Open Access Read More

Author(s): Harkamal Preet Singh

DOI: 10.5958/2321-581X.2016.00030.1         Access: Open Access Read More

Author(s): Santosh Kumar, N Mondal, Ajay Arora

DOI: 10.5958/2321-581X.2017.00036.8         Access: Open Access Read More

Author(s): M. Vijaya Sekhar Reddy

DOI:         Access: Open Access Read More

Author(s): Baljit Singh, A. K. Asati, Rakesh Kumar.

DOI: 10.5958/2321-581X.2018.00009.0         Access: Open Access Read More

Author(s): Sheela Shridhar

DOI: 10.52711/2321-581X.2023.00007         Access: Open Access Read More

Research Journal of Engineering and Technology (RJET) is an international, peer-reviewed, research journal aiming at promoting and publishing original high quality research in all disciplines of engineering sciences and technology....... Read more >>>

RNI: Not Available                     
DOI: 10.5958/2321-581X 


Recent Articles




Tags